weighing scale load cell amplifier DJ04-2 RS485 digital junction box weighing transmitter with modbus for load cell


Digital junction box / weighing transmitter with RS485 output +modbus
The digital junction box is based on resistance strain sensor as signal source, It is composed of 24bits Σ-Δ type A/D conversion technology and The 8 bit single chip microcomputer etc.large-scale integrated circuit. It is with high accuracy, high reliability.
Digital junction box / weighing transmitter Main functions:
¨ panel keyboard settings, capacity calibration
¨ Has function to display weight setting.
¨ Can point out failures, operational error.
¨ RS485 output,Can set the corresponding weight value of 4mA and 20mA.

2. Main Technical Parameters of  Digital junction box / weighing transmitter 

¨ 2.1 A/D sampling rate:  7.5 Times/s~240Times/s optional
¨ 2.2 Internal resolution:  24bits
¨ 2.3 Non-linearity:  ≤0.005%F.S
¨ 2.4 Zero drift:  ≤0.2μV
¨ 2.5 Temperature coefficient of capacity:   ≤10ppm/
¨ 2.6 Net input signal range of full capacity:   2~20mV
¨ 2.7 Initial weight signal range: -1~+9mV
¨ 2.8 Analog input signal sensitivity:0.5uV /d(Minimum)
          1.5uV/d(Recommended)
¨ 2.9 Zeroing range: 100%FS
¨ 2.11 Display: 6 red LED digital tubes(height of word is 14mm
¨ 2.14 Amibent temperature of operation: -5~ 45
¨ 2.15 Relative humidity: <= 90%(Non condensing)
¨ 2.16 Power supply: +18 ~ +26 VDC,0.5A
2.17 Sensor bridge excitation: DC 5V,can connect 6 load cells of 350 ohms or 12 load cells of 750 ohms.
Packaging details

  • Unit Type: piece
  • Package Weight: 1.000kg (2.20lb.)
  • Package Size: 5cm x 5cm x 5cm (1.97in x 1.97in x 1.97in)

Load cell amplifier weight transmitter

Load cell amplifier IN-A2PS

Replace ANYLOAD A2P Load Cell Amplifier,Replace ANYLOAD A2P Load Cell Amplifierhttp://www.china-industrymart.com/load-cell-amplifier-weight-transmitter_p0203.html analogue load cell amplifier, load cell amplifier,
strain gage amplifier, strain gauge amplifier
Load cell amplifier weight transmitter-INA2PSLoad cell amplifier weight transmitter-INA2PS



Built-in 24 bits Σ-Δ integrated ADC chip for weighing conversion;
Full digital conversion, no potentiometer or any other analog conditioning components;
Analog output two-button calibration, it only needs calibrate once of zero and full.
1 Accuracy: 1/10000
2 Non-linearity: ≤0.008%F.S
3 Zero temperature drift: ≤0.4μV/℃
4 Temperature coefficient of span: ≤10ppm/℃
5 Net input range of full capacity: -30 mV ~ +30mV
6 Sensitivity of analog input signal: 0.5uV /d (Min.)
1.5uV/d (Recommend)
7 Calibration range: +- 50%FS
8 Display: No display
9 Working temperature: -30℃~ 60℃
10 Relative humidity: ≤ 90%(No condensation)
11 Power supply: +18 ~ +26VDC,>0.5A
12Load cell bridge voltage: DC 5V 1.5A Can max connect with 8 pieces of load cells whose impedance > 350Ω
13 Output optional: 0~5V,0~10V,4~20mA(DIP switch selection)



Wiring:
Load cell amplifier weight transmitter-INA2PS

+E: load cell power supply +
-E: load cell power supply -
GND: shield
+S: feedback signal +
-S: Feedback signal -